June 2026 release

The latest version of the software are available to our customers now for download from the Support web site: access your Support area.

Not yet a Fives ProSim’s customer? Contact us for more information about our software and services.

 

 

BatchReactor 2.0.8

  • To clarify, two rarely used buttons have been removed from the toolbars, but their actions are still accessible via the menus. The “Refresh” action (update the screen) is now available via the “Edit / Refresh F5” menu. Direct access to the global compounds list is now possible via the Configuration / Global component list…“ menu.
  • The table of events in the monitoring window has been improved. A column indicating the type of the event has been added. Now, its status (displayed or not) is saved when the file is saved.

 

BatchColumn 2.0.8

  • To clarify, two rarely used buttons have been removed from the toolbars, but their actions are still accessible via the menus. The “Refresh” action (update the screen) is now available via the “Edit / Refresh F5” menu. Direct access to the global compounds list is now possible via the Configuration / Global component list…“ menu.
  • The action buttons on fractions or partial flow rates of the initial load and feeds available have been revised. It is now easier to copy/paste this information from Excel for example.
  • It is now possible to add a feed directly to the decanter.
  • The table of events in the monitoring window has been improved. A column indicating the type of the event has been added. Now, its status (displayed or not) is saved when the file is saved.

 

ProSec 3.7.13

  • It is now possible to generate files in CSV format. These files contain either data or results. This option is available via the “Results parameters” button and window. There will be one folder per simulation and per CO-ProSec modules present in a simulation. They are located at the same level as the simulation file. It’s possible to select the separator (comma or semi-comma) used to separate the values. A “ReadMe.txt” file, placed in the main directory, details the contents of each CSV file.

ProSIMPLUS 3.7.13

  • New functionalities have been added to the plug flow reactor in order to display the reaction rates profiles by reaction and by compound depending on the length of the equipment.These new profiles are available in the “Profiles” tab of the unit operation.
  • A new example has been created. After installing the new version, the examples are available using one of the following two methods:

    Examples are automatically installed with the new version of the tool in the “Example” folder installed on your computer accessible via the next path “..\ProSim\Examples\ProSimPlus Standard \”

    The examples are also accessible via the ProSim website with your username and password (https://www.prosim.net/en/log-in/)

    The new example is: “HIGH TEMPERATURE HEAT PUMP”

ProSIMPLUS HN03 3.7.13

  • New functionalities have been added to the plug flow reactor in order to display the reaction rates profiles by reaction and by compound depending on the length of the equipment.These new profiles are available in the “Profiles” tab of the unit operation.

Bonjour

Comment peut-on vous aider ?
Une question sur nos logiciels de simulation et/ou services, contactez-nous.